| Width | 70 |
|---|---|
| Model | Compact |
| Height | 90 |
| Depth | 70 |
| With display | No |
| Suitable for safety functions | No |
| Number of digital inputs | 8 |
| Number of digital outputs | 8 |
| Number of analogue inputs | 2 |
| Number of analogue outputs | 0 |
| Voltage type of supply voltage | DC |
| Type of memory | RAM |
| Memory size | 640 |
| Processing time (1K, binary operation) | 0 |
| Max. number of addressable analogue I/O-ports | 114 |
| Max. number of addressable digital I/O-ports | 264 |
| Supporting protocol for LON | No |
| Number of HW-interfaces industrial Ethernet | 1 |
| Number of HW-interfaces RS-232 | 1 |
| Number of HW-interfaces RS-422 | 0 |
| Number of HW-interfaces RS-485 | 1 |
| Number of HW-interfaces serial TTY | 0 |
| Number of HW-interfaces USB | 1 |
| Number of HW-interfaces parallel | 0 |
| Number of HW-interfaces other | 0 |
| With optical interface | No |
| Additional program memory possible | Yes |
| Supporting protocol for TCP/IP | Yes |
| Supporting protocol for ASI | No |
| Supporting protocol for PROFIBUS | No |
| Supporting protocol for CAN | No |
| Supporting protocol for INTERBUS | No |
| Supporting protocol for KNX | No |
| Supporting protocol for MODBUS | Yes |
| Supporting protocol for Data-Highway | No |
| Supporting protocol for DeviceNet | No |
| Supporting protocol for SUCONET | No |
| Supporting protocol for other bus systems | No |
| Redundancy | No |
| Rail mounting possible | Yes |
| Explosion safety category for gas | None |
| Explosion safety category for dust | None |
| System accessory | No |
| Appendant operation agent (Ex ia) | No |
| Appendant operation agent (Ex ib) | No |
| Supporting protocol for SERCOS | No |
| Supporting protocol for INTERBUS-Safety | No |
| Category according to EN 954-1 | 1 |
| Number of HW-interfaces PROFINET | 0 |
| Number of HW-interfaces Wireless | 0 |
| Front build in possible | No |
| Rack-assembly possible | No |
| Wall mounting/direct mounting | Yes |
| Radio standard Bluetooth | No |
| Radio standard WLAN 802.11 | No |
| IO link master | No |
| Number of relay outputs | 8 |
| Max. number of time switches | 255 |
| Performance level acc. to EN ISO 13849-1 | None |
| Supporting protocol for AS-Interface Safety at Work | No |
| Supporting protocol for DeviceNet Safety | No |
| Supporting protocol for EtherNet/IP | No |
| Supporting protocol for Foundation Fieldbus | No |
| Supporting protocol for PROFINET CBA | No |
| Supporting protocol for PROFINET IO | No |
| Supporting protocol for PROFIsafe | No |
| Supporting protocol for SafetyBUS p | No |
| Supply voltage AC 50 Hz | 0 - 0 |
| Supply voltage AC 60 Hz | 0 - 0 |
| Supply voltage DC | 19.2 - 28.8 |
| Radio standard GPRS | No |
| Radio standard GSM | No |
| Radio standard UMTS | No |
| SIL according to IEC 61508 | None |