| Width | 125 |
|---|---|
| Height | 18 |
| Depth | 65 |
| Input current at signal 1 | 3 |
| Suitable for safety functions | No |
| Number of digital inputs | 0 |
| Number of digital outputs | 2 |
| Time delay at signal exchange | 0.925 - 1.35 |
| Voltage type of supply voltage | AC |
| Supporting protocol for LON | No |
| Number of HW-interfaces industrial Ethernet | 0 |
| Number of HW-interfaces RS-232 | 0 |
| Number of HW-interfaces RS-422 | 0 |
| Number of HW-interfaces RS-485 | 0 |
| Number of HW-interfaces serial TTY | 0 |
| Number of HW-interfaces parallel | 0 |
| Number of HW-interfaces other | 0 |
| With optical interface | No |
| Type of voltage (input voltage) | DC |
| Supporting protocol for TCP/IP | Yes |
| Supporting protocol for ASI | No |
| Supporting protocol for PROFIBUS | Yes |
| Supporting protocol for CAN | Yes |
| Supporting protocol for INTERBUS | Yes |
| Supporting protocol for KNX | No |
| Supporting protocol for MODBUS | Yes |
| Supporting protocol for Data-Highway | No |
| Supporting protocol for DeviceNet | Yes |
| Supporting protocol for SUCONET | No |
| Supporting protocol for other bus systems | No |
| Output current | 0 |
| Short-circuit protection, outputs available | No |
| Type of digital output | None |
| Type of electric connection | Screw connection |
| Rail mounting possible | No |
| Explosion safety category for gas | None |
| Explosion safety category for dust | None |
| Fieldbus connection over separate bus coupler possible | Yes |
| System accessory | Yes |
| Appendant operation agent (Ex ia) | No |
| Appendant operation agent (Ex ib) | No |
| Degree of protection (IP) | IP20 |
| Supporting protocol for SERCOS | No |
| Supporting protocol for INTERBUS-Safety | No |
| Category according to EN 954-1 | 1 |
| Number of HW-interfaces PROFINET | 0 |
| Number of HW-interfaces Wireless | 0 |
| Front build in possible | No |
| Rack-assembly possible | No |
| Wall mounting/direct mounting | No |
| Radio standard Bluetooth | No |
| Radio standard WLAN 802.11 | No |
| IO link master | No |
| Performance level acc. to EN ISO 13849-1 | None |
| Supporting protocol for AS-Interface Safety at Work | No |
| Supporting protocol for DeviceNet Safety | No |
| Supporting protocol for EtherNet/IP | Yes |
| Supporting protocol for Foundation Fieldbus | No |
| Supporting protocol for PROFINET CBA | No |
| Supporting protocol for PROFINET IO | No |
| Supporting protocol for PROFIsafe | No |
| Supporting protocol for SafetyBUS p | No |
| Supply voltage AC 50 Hz | 115 - 115 |
| Supply voltage AC 60 Hz | 115 - 115 |
| Supply voltage DC | 0 - 0 |
| Permitted voltage at output | 0 - 0 |
| Permitted voltage at input | -3 - 30 |
| Type of output voltage | DC |
| Digital inputs configurable | No |
| Digital outputs configurable | No |
| Radio standard GPRS | No |
| Radio standard GSM | No |
| Radio standard UMTS | No |
| SIL according to IEC 61508 | None |